Basic Properties
Place of Origin: Zhejiang, China
Brand Name: Zhonglu
Model Number: GGD
Trading Properties
Minimum Order Quantity: 1 set
Price: $500-2,000 / set
Product Summary
Product Overview The 0.4kV Variable Frequency Constant Pressure Water Supply Control Cabinet is an automated solution designed to maintain a consistent water pressure across various consumption demands. By utilizing advanced Variable Frequency Drive (VFD) technology, the system adjusts the motor ...

Product Details

Highlight:

Constant Pressure Water Supply Control Cabinets

,

IEC 61439 Water Supply Control Cabinets

Rated Current: 100A~6300A
Rated Voltage: 0.4KV
Product Name: Low Voltage Withdrawable Switchgear Assembly
Ambient Temperature: -5℃ ~+40℃
Altitude: ≤2000M
Voltage: 0.4KV
Electricity: 100~6300A
Color: 7035, Customizable
Material: AI-Zn-plated Steel Sheet
Temperature: -25℃~55℃
Frequency: 50HZ
Application: Indoors
Product Description
Product Overview

The 0.4kV Variable Frequency Constant Pressure Water Supply Control Cabinet is an automated solution designed to maintain a consistent water pressure across various consumption demands. By utilizing advanced Variable Frequency Drive (VFD) technology, the system adjusts the motor speed of the pumps in real-time, matching the output to the actual water demand.

This cabinet features a high-reliability "One-Duty, One-Standby" (1W1S) configuration. In this setup, two pumps rotate their operational roles to ensure even wear, while providing an immediate backup if the primary pump fails. It is the premier choice for municipal water works, high-rise residential buildings, and industrial cooling systems where 24/7 water availability is mandatory.


Key Technical Advantages
  • Energy Efficiency (VFD Driven): Reduces power consumption by up to 30%–50% compared to traditional across-the-line starters by preventing pumps from running at full speed during low-demand periods.

  • Soft Start & Stop Functionality: Eliminates "Water Hammer" effects in piping systems, significantly extending the lifespan of valves, seals, and pipe joints.

  • Automatic Duty-Cycle Rotation: The integrated PLC or smart pump controller automatically alternates the lead pump based on a set timer, ensuring balanced mechanical wear and preventing pump seizure.

  • Precise Pressure PID Control: Integrated with a pressure transmitter (sensor) feedback loop to maintain a stable set-point within ±0.01MPa, regardless of flow fluctuations.

  • Comprehensive Motor Protection: Built-in safeguards against over-voltage, under-voltage, phase loss, dry running (low water level), and motor overload.


Technical Specifications
Feature Detailed Specifications
Rated Voltage (Ue) AC 380V / 400V / 415V (3-Phase)
Control Power Range 0.75kW - 315kW (Customizable)
VFD Component ABB / Siemens / Schneider / Yaskawa (Optional)
Control Logic One-Duty One-Standby / Multi-Pump Parallel
Pressure Stability < ±0.01MPa
Enclosure Material Cold-Rolled Steel / Stainless Steel (IP42 - IP55)
Cooling System Temperature-Controlled Forced Air Cooling
Compliance IEC 61439, CE, ISO9001

Primary Application Scenarios
  1. High-Rise Buildings: Managing domestic water pressure for residential towers, hotels, and office complexes.

  2. Industrial Cooling Systems: Maintaining constant flow and pressure for factory heat exchangers and cooling towers.

  3. Irrigation & Agriculture: Smart pressure management for large-scale sprinkler and drip irrigation networks.

  4. Firefighting Auxiliary Systems: Keeping the fire main pressurized (Jockey Pump control) to ensure immediate readiness.


Why Specify Our VFD Control Cabinets?
  • User-Friendly HMI: Features an intuitive digital display on the cabinet door, showing real-time frequency, output pressure, current, and fault history.

  • Smart Dual-Source Switching: Includes manual/automatic bypass switches, allowing the operator to run pumps directly from the grid in the unlikely event of a VFD failure.

  • Premium Enclosure Quality: All cabinets undergo anti-corrosion treatment and are finished with a high-durability epoxy powder coating for long-term industrial use.

  • Ready for SCADA: Supports RS485/Modbus communication, enabling remote monitoring and control from a centralized building management system (BMS).


FAQ

Q: Can this cabinet handle more than two pumps?

A: Yes. While the "One-Duty One-Standby" is the standard, we offer custom configurations for Three-Pump (Two-Duty One-Standby) or larger parallel arrays for high-flow municipal applications.

Q: Does the system protect against dry running?

A: Absolutely. The cabinet is designed to interface with liquid level sensors in the suction tank. If the water level drops too low, the system will automatically shut down the pumps to prevent mechanical damage.

Q: Is it easy to change the pressure set-point?

A: Yes. The operator can easily adjust the target pressure directly via the digital keypad on the cabinet door without opening the enclosure.

0.4KV Variable Frequency Constant Pressure Water Supply Control Cabinets IEC 61439 0
Low voltage withdrawable switchgear assembly

GGD low voltage withdrawable switchgear assembly (hereinafter referred to as device) is the former state Ministry of Machinery, the Ministry of Electric power joint design group according to the industry authorities, the majority of power users and design units developed in line with the national conditions, with high technical performance indicators, can adapt to the development of the power market needs and can compete with the existing introduced products. In July 1996, the device passed the appraisal jointly presided over by two departments in Shanghai, and received the attention and affirmation of the production and manufacturing units and power use departments.

The device is suitable for power plant, petroleum, chemical, metallurgy, textile, high-rise building and other industries of power distribution system. In large power plants, petrochemical systems and other places with a high degree of automation, requiring computer interface, as a three-phase AC 50(60)Hz, rated working voltage 380V, rated current 4000A and below the distribution, centralized control of the motor, reactive power compensation of the low-voltage distribution device.

The device conforms to IEC439-1 and GB7251.1 standards.

Operating environment conditions
  1. The ambient air temperature is not higher than +40℃, not lower than -5℃, and the average temperature within 24 hours is not higher than +35℃.
  2. The relative humidity at high temperature is not more than 50%, in the lower temperature is allowed to have a high relative humidity, such as +20℃ at 90%, but should take into account the temperature change, may occasionally produce moderate condensation.
  3. The altitude does not exceed 2000 meters.
  4. Installation tilt shall not exceed 5°.
  5. No dust, corrosive gas and rain immersion indoors.
0.4KV Variable Frequency Constant Pressure Water Supply Control Cabinets IEC 61439 1 0.4KV Variable Frequency Constant Pressure Water Supply Control Cabinets IEC 61439 2 0.4KV Variable Frequency Constant Pressure Water Supply Control Cabinets IEC 61439 3 0.4KV Variable Frequency Constant Pressure Water Supply Control Cabinets IEC 61439 4 0.4KV Variable Frequency Constant Pressure Water Supply Control Cabinets IEC 61439 5 0.4KV Variable Frequency Constant Pressure Water Supply Control Cabinets IEC 61439 6 0.4KV Variable Frequency Constant Pressure Water Supply Control Cabinets IEC 61439 7 0.4KV Variable Frequency Constant Pressure Water Supply Control Cabinets IEC 61439 8 0.4KV Variable Frequency Constant Pressure Water Supply Control Cabinets IEC 61439 9 0.4KV Variable Frequency Constant Pressure Water Supply Control Cabinets IEC 61439 10 0.4KV Variable Frequency Constant Pressure Water Supply Control Cabinets IEC 61439 11
Specification

Product name

Low voltage withdrawable switchgear assembly

Application

The device is suitable for power plant, petroleum, chemical, metallurgy, textile, high-rise building and other industries of power distribution system

Place of origin

Zhejiang,China

Recommend Products
0.4KV Variable Frequency Constant Pressure Water Supply Control Cabinets IEC 61439 12
Company Profile
0.4KV Variable Frequency Constant Pressure Water Supply Control Cabinets IEC 61439 13 0.4KV Variable Frequency Constant Pressure Water Supply Control Cabinets IEC 61439 14
Certifications
0.4KV Variable Frequency Constant Pressure Water Supply Control Cabinets IEC 61439 15
Customer Photos
0.4KV Variable Frequency Constant Pressure Water Supply Control Cabinets IEC 61439 16
Product packaging
0.4KV Variable Frequency Constant Pressure Water Supply Control Cabinets IEC 61439 17
FAQ
0.4KV Variable Frequency Constant Pressure Water Supply Control Cabinets IEC 61439 18 0.4KV Variable Frequency Constant Pressure Water Supply Control Cabinets IEC 61439 19
Related Products

Send An Inquiry